View: |
Part 1: Document Description
|
|
Citation |
|
|---|---|
|
Title: |
Replication data for: Dynamic Modelling and Validation of an Air-to-Water Reversible R744 Heat Pump for High Energy Demand Buildings |
|
Identification Number: |
doi:10.18710/0UMYZ9 |
|
Distributor: |
DataverseNO |
|
Date of Distribution: |
2021-12-09 |
|
Version: |
1 |
|
Bibliographic Citation: |
Artuso, Paolo; Tosato, Giacomo; Rosetti, Antonio; Minetto, Silvia; Marinetti, Sergio; Hafner, Armin; Banasiak, Krzysztof, 2021, "Replication data for: Dynamic Modelling and Validation of an Air-to-Water Reversible R744 Heat Pump for High Energy Demand Buildings", https://doi.org/10.18710/0UMYZ9, DataverseNO, V1 |
|
Citation |
|
|
Title: |
Replication data for: Dynamic Modelling and Validation of an Air-to-Water Reversible R744 Heat Pump for High Energy Demand Buildings |
|
Identification Number: |
doi:10.18710/0UMYZ9 |
|
Authoring Entity: |
Artuso, Paolo (National Research Council, Construction Technologies Institute) |
|
Tosato, Giacomo (Enex srl) |
|
|
Rosetti, Antonio (National Research Council, Construction Technologies Institute) |
|
|
Minetto, Silvia (National Research Council, Construction Technologies Institute) |
|
|
Marinetti, Sergio (National Research Council, Construction Technologies Institute) |
|
|
Hafner, Armin (NTNU – Norwegian University of Science and Technology) |
|
|
Banasiak, Krzysztof (Sintef Energy) |
|
|
Producer: |
NTNU – Norwegian University of Science and Technology |
|
Distributor: |
DataverseNO |
|
Distributor: |
NTNU – Norwegian University of Science and Technology |
|
Access Authority: |
Söylemez, Engin |
|
Depositor: |
Söylemez, Engin |
|
Date of Deposit: |
2021-12-06 |
|
Holdings Information: |
https://doi.org/10.18710/0UMYZ9 |
|
Study Scope |
|
|
Keywords: |
Engineering, Reversible heat pump, Air conditioning, Carbon dioxide, numerical simulation, Heat pump, integrated refrigeration system |
|
Abstract: |
In this dataset, data from the pre-commissioning tests of the MultiPACK unit for hotels that were carried out at the factory’s facilities were shared. The scheme of the refrigerating system is provided in Figure 1, while the characteristics of the main components are listed in Table 1. The unit has two semi-hermetic compressors (compressor(1) and compressor(2)), two brazed-plate gas-coolers (gas-cooler(1) and gas-cooler(2)), a finned-coil heat exchanger (gas-cooler/evaporator(3)), an internal heat exchanger (IHX) between the compressor suction line and gas-cooler outlet line, a back-pressure valve (BPV), a multi-ejector rack, a low-pressure receiver (LPR) and an electronic expansion valves (EEV(1)). The operation of the system can be switched between two main configurations, i.e. heat pump and chiller, by means of circulation valves located in the circuit. |
|
Methodology and Processing |
|
|
Sources Statement |
|
|
Data Access |
|
|
Notes: |
<a href="http://creativecommons.org/publicdomain/zero/1.0">CC0 1.0</a> |
|
Other Study Description Materials |
|
|
Related Publications |
|
|
Citation |
|
|
Title: |
Artuso, P., Tosato, G., Rossetti, A., Marinetti, S., Hafner, A., Banasiak, K., & Minetto, S. (2021). Dynamic Modelling and Validation of an Air-to-Water Reversible R744 Heat Pump for High Energy Demand Buildings. Energies, 14(24), Article 24. https://doi.org/10.3390/en14248238 |
|
Identification Number: |
10.3390/en14248238 |
|
Bibliographic Citation: |
Artuso, P., Tosato, G., Rossetti, A., Marinetti, S., Hafner, A., Banasiak, K., & Minetto, S. (2021). Dynamic Modelling and Validation of an Air-to-Water Reversible R744 Heat Pump for High Energy Demand Buildings. Energies, 14(24), Article 24. https://doi.org/10.3390/en14248238 |
|
Label: |
00_README_file.txt |
|
Notes: |
text/plain |
|
Label: |
01_Data_Heat-Pump_(Table-7).txt |
|
Notes: |
text/plain |
|
Label: |
02_Data_Chiller_(Table-8).txt |
|
Notes: |
text/plain |
|
Label: |
03_Data_Chiller-DHW_(Table-9).txt |
|
Notes: |
text/plain |
|
Label: |
04_Figure-1.Operating scheme of the refrigerating system.jpg |
|
Notes: |
image/jpeg |
|
Label: |
05_Figure-2.Schematic of the refrigerating system operating according to the simple heat pump configuration.jpg |
|
Notes: |
image/jpeg |
|
Label: |
06_Figure-3.Schematic of the refrigerating system operating according to the chiller configuration, single compressor, single evaporator and hot water production.jpg |
|
Notes: |
image/jpeg |
|
Label: |
07_Figure-4.Schematic of the refrigerating system operating according to the chiller configuration, two compressors and two evaporators.jpg |
|
Notes: |
image/jpeg |
|
Label: |
08_Figure-5a.Comparison between nominal and experimental performance for fixed speed compressor (Compressor1 and inverter modulated compressor Compressor2_MassFlowRate.jpg |
|
Notes: |
image/jpeg |
|
Label: |
09_Figure-5b.Comparison between nominal and experimental performance for fixed speed compressor Compressor1 and inverter modulated compressor Compressor2_ElectricalPowerConsumption.jpg |
|
Notes: |
image/jpeg |
|
Label: |
10_Figure-6.Discretization heat exchanger.jpg |
|
Notes: |
image/jpeg |
|
Label: |
11_Figure-7.Operation of the heat-pump in steady state conditions, EXP vs. NUM.jpg |
|
Notes: |
image/jpeg |
|
Label: |
12_Figure-8.Trend of the gas-cooler heat flow rate as a function of time, EXP vs. NUM.jpg |
|
Notes: |
image/jpeg |
|
Label: |
13_Figure-9.Operation of the chiller configuration with a single evaporator without DHW production.jpg |
|
Notes: |
image/jpeg |
|
Label: |
14_Figure-10.Operation of the chiller configuration with a single evaporator and DHW production.jpg |
|
Notes: |
image/jpeg |
|
Label: |
15_Figure-11.Simulation of the heating system coupled with the brazed plate gas-cooler of the heat pump.jpg |
|
Notes: |
image/jpeg |
|
Label: |
16_Figure-12.Trend of the gas-cooler heat flow rate, DHW and SH demand during the dynamic simulation.jpg |
|
Notes: |
image/jpeg |
|
Label: |
17_Figure-13.Trend of rotation speed of the compressors during the dynamic simulation.jpg |
|
Notes: |
image/jpeg |
|
Label: |
18_Figure-14.Trend of evaporation pressure during the dynamic simulation.jpg |
|
Notes: |
image/jpeg |
|
Label: |
19_Figure-15.Trend of COP during the dynamic simulation.jpg |
|
Notes: |
image/jpeg |
|
Label: |
20_Table-1.Geometric dimensions of the system main components of the system.JPG |
|
Notes: |
image/jpeg |
|
Label: |
21_Table-2.Accuracy of the instruments.JPG |
|
Notes: |
image/jpeg |
|
Label: |
22_Table-3.Maximum uncertainties of the main heat flow rate evaluation.JPG |
|
Notes: |
image/jpeg |
|
Label: |
23_Table-4.Empirical correlation utilized in the case of finned coil heat exchanger.JPG |
|
Notes: |
image/jpeg |
|
Label: |
24-Table-5.Empirical correlation utilized in the case of brazed plate heat exchanger.JPG |
|
Notes: |
image/jpeg |
|
Label: |
25_Table-6.Empirical correlation utilized in the case of internal heat exchanger.JPG |
|
Notes: |
image/jpeg |
|
Label: |
26_Table-7.Comparison between experimental data and simulation results, heat pump configuration.JPG |
|
Notes: |
image/jpeg |
|
Label: |
27_Table-8.Comparison between experimental data and simulation results, chiller configuration, brazed plate gas.JPG |
|
Notes: |
image/jpeg |
|
Label: |
28_Table-9.Comparison between experimental data and simulation results, chiller configuration, brazed plate gas cooler included.JPG |
|
Notes: |
image/jpeg |
|
Label: |
29_Table-10.Water set-point temperature and return temperature.JPG |
|
Notes: |
image/jpeg |
|
Label: |
30_Table-11.Mean value of high pressure, evaporation pressure, water mass flow rate at the gas-cooler and gas-cooler heat flow rate and COP during the simulation time.JPG |
|
Notes: |
image/jpeg |